To Pin a Compatible Unit to a Feature

  1. On the Features page of the Job Default Assistant, select the feature type that you want to link to a compatible unit.
  2. From the Job Default menu, choose Feature Properties to open the Placement Defaults dialog box.
  3. Or right-click the feature and choose Feature Properties from the shortcut menu.
  4. To modify current attribute values in the Default Values list on the Attributes page, click the value to make it editable and select a new value from the drop-down list. Note: Making changes to the current values will change the units displayed in the Compatible Unit Matches list.
  5. In the Compatible Unit Matches list, click the unit that you want to pin to the feature type and then click OK.